A generic non-invasive neuromotor interface for human-computer interaction

TL;DR A dry-electrode wristband reads muscle signals (sEMG), and networks trained on data from thousands of people decode wrist movement, finger gestures and handwriting for new users without calibration. Naive users reach 0.88 gesture detections per second and handwrite at 20.9 words per minute; 20 min of a user's own data cuts handwriting errors a further 16%.
What they do
Meta’s CTRL-labs built a wristband that records surface electromyography (sEMG), the electrical activity of the forearm muscles, and decoders that work for people they were never trained on, unlike earlier high-bandwidth interfaces, which were invasive and calibrated per person. The generic models drive 1D cursor control from wrist angle, nine thumb and finger gestures, and handwriting with an imaginary pen.
How it works
- Hardware. The sEMG-RD is a wireless dry-electrode band with 16 bipolar channels sampled at 2 kHz with 2.46 μVrms noise, made in four sizes. It is sensitive enough to pick up putative single motor-unit action potentials.
- Data at scale. Automated prompting software recorded 162 to 6,627 participants per task, re-donning the band between sessions. Wrist-angle labels come from motion capture.
- Models. An LSTM regresses wrist-angle velocity from spectral features; a 1D convolution and three LSTM layers detect gestures from raw sEMG; a 15-layer streaming Conformer trained with CTC transcribes characters. The wrist and handwriting models average over ±1-channel rotations of the band.
- Personalization. Optionally fine-tune the whole generic handwriting model on one user’s data.
Results
- Single-person gesture models transfer poorly to others; generic models improve as a power law in training participants and model size.
- Offline on held-out people: over 90% accuracy for gestures and handwriting, and under 13°/s error on wrist velocity.
- Closed loop, naive users completed every trial: 0.66 target acquisitions/s with the wrist (1.51 s median acquisition vs 0.68 s on a trackpad), 0.88 gestures/s (1.45 with a game controller) and 20.9 words/min handwriting (25.1 writing on a surface without a pen).
- 20 min of personal data improves the 6,400-participant handwriting model’s median error by 16%. Gains are largest for users the generic model serves worst; a model personalized to one person helped another in only 7% of pairs.
Limitations
Every sEMG decoder is slower than its conventional baseline. Continuous control is shown for one degree of freedom only, and some participants needed coaching during evaluation. All participants were able-bodied, and the authors say it is unclear whether the models generalize to clinical populations.
Figures




Abstract
Since the advent of computing, humans have sought computer input technologies that are expressive, intuitive and universal. While diverse modalities have been developed, including keyboards, mice and touchscreens, they require interaction with a device that can be limiting, especially in on-the-go scenarios. Gesture-based systems use cameras or inertial sensors to avoid an intermediary device, but tend to perform well only for unobscured movements. By contrast, brain–computer or neuromotor interfaces that directly interface with the body’s electrical signalling have been imagined to solve the interface problem, but high-bandwidth communication has been demonstrated only using invasive interfaces with bespoke decoders designed for single individuals. Here, we describe the development of a generic non-invasive neuromotor interface that enables computer input decoded from surface electromyography (sEMG). We developed a highly sensitive, easily donned sEMG wristband and a scalable infrastructure for collecting training data from thousands of consenting participants. Together, these data enabled us to develop generic sEMG decoding models that generalize across people. Test users demonstrate a closed-loop median performance of gesture decoding of 0.66 target acquisitions per second in a continuous navigation task, 0.88 gesture detections per second in a discrete-gesture task and handwriting at 20.9 words per minute. We demonstrate that the decoding performance of handwriting models can be further improved by 16% by personalizing sEMG decoding models. To our knowledge, this is the first high-bandwidth neuromotor interface with performant out-of-the-box generalization across people.
Summaries are written automatically from each paper's text. Figures and videos come from the paper and its project page; all credit goes to the authors.